Link to Commscope V4SSPP-360S-F Antenna (~1,695 to 5,925 MHz)
The following 4G/5G canister antenna, with capability of 9,080 Watts ERP violates Title 47 CFR §1.1307, Table 1
Any person can file an FCC Complaint and stop construction waiting for FCC Determination if EA must be prepared — by rule rule, it must (See NEPA Strategies here).
Link to §1.1307 — Actions that may have a significant environmental effect, for which Environmental Assessments (EAs) must be prepared.
Cellular Radiotelephone Service (subpart H of part 22):
Non-building-mounted antennas: height above ground level to lowest point of antenna < 10 meters (33 ft. 8 in.) and total power of all channels > 1000 Watts ERP
Frequency (MHz) |
Ant. Gain |
Max Power × Power Ratio |
Watts ERP x # Ports |
Total ERP |
|
---|---|---|---|---|---|
1695–1920 | 7.2 | 5.2 | 125 × 5.2 = | 650 × 4 = | 2,600 |
1920–2180 | 7.3 | 5.4 | 125 × 5.4= | 675 × 4 = | 2,700 |
2300–2690 | 8.4 | 6.9 | 125 × 6.9 = | 862.5 × 4 = | 3,450 |
3300–3800 | 4.4 | 2.8 | 50 × 2.8 = | 140 × 2 = | 280 |
5150–5925 | 4.0 | 2.5 | 10 × 2.5 = | 25 × 2 = | 50 |
Total Max ERP Output Capability | 9,080 W | ||||
with 3dB Override . . . | 18,160 W |
Link to Maximum Output Power for Street Macro 6701 (~28,000 MHz) . . .
and Dimensions of the Box-Shaped Non-Compliance Boundary (cubic feet)
Band |
Total Nominal |
Power |
Antenna |
Maximum |
Total Max. |
Distance |
Width |
Height |
Volume |
Equiv. # |
|
---|---|---|---|---|---|---|---|---|---|---|---|
B261 | 56 dBM | 0.51 Watt | 28.6 dBi | 725 | 0.51 × 725 = 370 Watts | 370 W × 4 Beams = 1,480 W | 5.9 ft. | 6.9 ft. | 3.3 ft. | ~135 cu. ft. | 4.5 full-size refrigerators |
The specs call for three (3) Ericcson Street Macro 6701 Units, so . . . 3 × 1,480 Watts = 4,440 Watts ERP (also violates Title 47 CFR §1.1307, Table 1)
2290 East Helen Street, Tucson
(Lat/Long: 32.237212, -110.938227)